Showing results: 31 - 39 of 39 items found.
-
Extech 380580 -
Extech Instruments Corporation
The 380580 is a Battery Powered Milliohm Meter. This milliohm meter features a high accuracy, a high resolution, portable milliohm meter battery operated for field use, four terminal Kelvin measurements, and Over-temperature and over-voltage protection. CE certified. Complete with 8AA batteries, and 2 sets of test leads (4 wire with 4 alligator clips and 4 wire with 2 Kelvin alligator clips).
-
16047A -
Keysight Technologies
The 16047A is designed for impedance evaluation of axial/radial lead type devices of up to 13MHz. The 16047A employs Kelvin contacts which realize a wide impedance measurement range. The contact tip can be changed according to the device shape.
-
BS407 -
Aim-TTi
High basic accuracy of 0.1%Wide range of 1 µΩ to 20 kΩCurrent reversal switch for detecting thermal EMF effectsCurrent diversion switch for easy zeroingFour terminal measurement using Kelvin clip leads (supplied)Battery operation with built-in charger20mV clamp for "dry circuit" testing
-
Educated Design & Development, Inc.
Up to 8 resistance reading channels, 4-wire methodUp to 12 temperature reading chanels, use of Type K, 24 AWG, Teflon thermocouplesIn the Box:8 - data cable (Cat5e) to connect the isolation modules to the Resistance Reading Channels8 - Isolation Module connected between the HOT-30 and EUT (Equipment Under Test) to isolate high voltage8 - Banana Jack Sets (2 red, 2 black), to replace Kelvin Leads in tight places8 - Kelvin Probe Set12 - 72 inch K Type Thermocouple1 - USB2.0 Type A (standard) to Type B USB cable
-
LCR400 -
Aim-TTi
0.1% basic measurement accuracyDual 5 digit high brightness displaysAutomatic component recognitionBuilt-in 4 terminal component fixtureLimits comparator with 8 Pass bins plus 2 Fail binsThree test frequencies, switchable biasRS232 interface standardOptional SMD tweezers, BNC connectors, Kelvin Clip test lead set, and PC logging software
-
LOM-510A -
IET Labs
The Micro-Ohmmeter has 4 digits, 0.02% basic accuracy and 1 resolution. The 4-terminal kelvin measurement connection minimizes lead resistance errors and 80 dB of ac noise rejection provides rock-steady readings even in noisy locations. The micro-ohmmeter comes with rugged 4-terminal test clips and a large selection of optional probes, clips and fixtures allowing attachment to any low-resistance unknown.
-
R1L-BR -
TEGAM Inc.
The R1L-B series Ohmmeter/Bonding Tester is a digital microohmmeter designed to measure resistances from 10 to 20 . It is used in applications such as metal bonding, switch, circuit breaker, circuit resistance and other contact and connection resistance tests as well as higher resistance measurements for circuit analysis and resistor testing up to 20 . The instruments utilize the four-terminal, Kelvin technique to eliminate errors caused by the resistance of the leads. Resistance readings are viewed on a 3 1/2 digit display,
-
A694 -
AGM Elettronica
The A694 is a short circuit locator designed for fault location in metallic cables. The instrument measures the ratio of the resistances of the two sections of failed conductor using a four-wire "Kelvin" connection, thus eliminating errors associated with contact resistances of the test leads. With the A694 you can determine if the cable has more than a short and locate the first and the last fault. The instrument locates fault with an insulation resistance up to 5 Mohms in cables that have a total resistance greater than 0.1 ohm and less than 40 kohms. The distance to fault is measured as a percentage of the total length of cable and is displayed on a large LCD display.
-
A910 -
AGM Elettronica
The A910 is a short circuit locator designed for fault location in power cables. The instrument measures the ratio of the resistances of the two sections of failed conductor using a four-wire "Kelvin" connection, thus eliminating errors associated with contact resistances of the test leads. With the A910 you can determine if the cable has more than a short and locate the first and the last fault. The instrument locates fault with an insulation resistance up to 5 Mohms in cables that have a total resistance greater than 5mohm (approximately 90 m of 300 sqmm cable) and less than 30 kohms. The distance to fault is measured as a percentage of the total length of cable and is displayed on a large LCD display.